ITCertMaster provides a clear and superior solutions for each HP HP0-500 exam candidates. We provide you with the HP HP0-500 exam questions and answers. Our team of IT experts is the most experienced and qualified. Our test questions and the answer is almost like the real exam. This is really amazing. More importantly, the examination pass rate of ITCertMaster is highest in the worldwide.
There a galaxy of talents in the 21st century, but professional IT talents not so many. Society need a large number of professional IT talents. Now IT certification exam is one of the methods to inspect the employees' ability, but it is not so easy to is one of the way to IT certification exams. Generally, people who participate in the IT certification exam should choose a specific training course, and so choosing a good training course is the guarantee of success. ITCertMaster's training course has a high quality, which its practice questions have 95% similarity with real examination. If you use ITCertMaster's product to do some simulation test, you can 100% pass your first time to attend IT certification exam.
Never say you can not do it. This is my advice to everyone. Even if you think that you can not pass the demanding HP HP0-500 exam. You can find a quick and convenient training tool to help you. ITCertMaster's HP HP0-500 exam training materials is a very good training materials. It can help you to pass the exam successfully. And its price is very reasonable, you will benefit from it. So do not say you can't. If you do not give up, the next second is hope. Quickly grab your hope, itis in the ITCertMaster's HP HP0-500 exam training materials.
There are too many variables and unknown temptation in life. So we should lay a solid foundation when we are still young. Are you ready? Working in the IT industry, do you feel a sense of urgency? ITCertMaster's HP HP0-500 exam training materials is the best training materials. Select the ITCertMaster, then you will open your door to success. Come on!
Exam Code: HP0-500
Exam Name: HP (HP ProLiant Server Maintenance)
Guaranteed success with practice guides, No help, Full refund!
200 Questions and Answers
Updated: 2013-11-20
In recent years, fierce competition agitates the forwarding IT industry in the world. And IT certification has become a necessity. If you want to get a good improvement in your career, The method that using the ITCertMaster’s HP HP0-500 exam training materials to obtain a certificate is very feasible. Our exam materials are including all the questions which the exam required. So the materials will be able to help you to pass the exam.
HP0-500 Free Demo Download: http://www.itcertmaster.com/HP0-500.html
NO.1 .Which product reports prefailure on all Compaq SMART hard drives?
A. CIM
B. RBSU C. ACU D. SCU
Answer: A
HP test HP0-500 HP0-500 questions
NO.2 .What do Compaq hot-pluggable power supplies have that traditional power supplies do not?
A. higher current
B. higher voltage
C. microcontroller Self-Test
D. power Monitor Port
Answer: C
HP certification training HP0-500 HP0-500 HP0-500
NO.3 .Which utility is assists in planning and configuring Compaq racks?
A. RackManager
B. RackAssistant
C. RackIntegrator
D. RackBuilder Pro
Answer: D
HP certification HP0-500 HP0-500 HP0-500
NO.4 .Which step must be performed when upgrading a customer's ProLiant server from a Pentium II Xeon
to Pentium III Xeon processor?
A. Flash ROM before replacing processors.
B. Ensure all processors have the same frequency and cache size.
C. Mix cache sizes in pairs for sockets 1 and 3.
D. Upgrade terminator boards for all four sockets.
Answer: A
HP exam prep HP0-500 practice test HP0-500 demo HP0-500 pdf HP0-500 exam dumps HP0-500
NO.5 .What is used to disable a Compaq server serial port?
A. Compaq Insight Manager
B. System Board Switch
C. System Configuration Utility
D. Nothing, as it is disabled by default
Answer: C
HP test HP0-500 answers real questions HP0-500 HP0-500 test HP0-500 HP0-500
NO.6 .Which diagnostic mode tests individual components of a server?
A. Intermediate
B. Automatic
C. QuickCheck
D. Prompted
Answer: D
HP test questions HP0-500 certification HP0-500 pdf HP0-500 exam HP0-500 test questions
NO.7 .What action is recommended if the Server Health Driver consistently reports a correctable memory
error in the same location?
A. Run ERASE utility to clear the location.
B. Schedule downtime and replace memory.
C. This is normal and can be ignored.
D. Mark "repaired" in Insight Manager.
Answer: B
HP practice test HP0-500 braindump HP0-500 HP0-500 exam dumps
NO.8 .What is the advantage of having an online spare as part of a SMART array configuration?
A. The drive can be used for temporary data storage until another drive fails.
B. The array will not lose its fault tolerance in case of a single drive failure.
C. You always have a spare drive available to physically put in place of a failed drive without having to
order a spare drive.
D. You can load balance across the array.
Answer: B
HP HP0-500 questions HP0-500 answers real questions
NO.9 .What problem is indicated if the server powers up with no video and an audible POST error?
A. memory module not seated
B. monitor signal cable not connected
C. intermittent memory parity errors
D. monitor in power saver mode
Answer: A
HP practice test HP0-500 HP0-500 test questions HP0-500 HP0-500
NO.10 .What enables remote server management and control regardless of the operating system or condition
of the server?
A. CIM (Compaq Insight Manager)
B. SCU (System Configuration Utility)
C. Remote Utilities (from system Diagnostics menu)
D. RILOE (Remote Insight Light Out Edition option)
Answer: D
HP HP0-500 HP0-500 HP0-500 HP0-500 braindump HP0-500
NO.11 .Which action is required to safely replace non hot-pluggable components in servers with redundant
hot-pluggable power supplies?
A. Depress server On/Off switch from front panel.
B. Ensure DC LED indicator on the hot-pluggable power supply is inactive.
C. Remove AC power cord from the primary hot-pluggable power supply.
D. Remove AC power cords from all hot-pluggable power supplies.
Answer: D
HP HP0-500 exam simulations HP0-500 HP0-500 demo HP0-500
NO.12 .What capability do fans have in some hot-pluggable power supplies?
A. variable RPM, depending on thermal sensor readings
B. hot plug fan replacement
C. dual-power inputs for redundancy
D. redundant power supply fans
Answer: A
HP certification training HP0-500 HP0-500 pdf
NO.13 .A hard drive fails on a system with an on-line spare. When is it recommended that the failed drive be
replaced?
A. upon discovery of the failure
B. upon completion of rebuild of on-line spare
C. not needed, failed drive will perform self-repair
D. any time before rebuild of online spare is complete
Answer: B
HP HP0-500 HP0-500 questions HP0-500 dumps HP0-500 exam simulations
NO.14 .Which Compaq utility is used to configure Online Spare memory?
A. Rapid Raid Utility
B. Raid Builder for AMP
C. ROM-based Setup Utility
D. SmartStart
Answer: C
HP HP0-500 test answers HP0-500 HP0-500 test
NO.15 .Which resources could be used to help isolate correctable memory errors?
A. SSD and DAAD
B. ACU and SmartStart
C. Server Health Logs and Integrated Management Log
D. QRG (Quick Reference Guide) and Inspect
Answer: C
HP HP0-500 test answers HP0-500 braindump HP0-500
NO.16 .Which network interface controller configuration can support redundant NICs?
A. one dual-port fast Ethernet network controller
B. one 16/4 token ring network controller connected to a managed hub
C. one fast Ethernet network controller connected to a second server
D. one fast Ethernet network controller connected to a router
Answer: A
HP HP0-500 study guide HP0-500 HP0-500
NO.17 .Which Compaq server component is covered under prefailure warranty?
A. DIMM memory
A. hard disk controller
B. recovery server option
C. network interface controller
Answer: A
HP exam HP0-500 practice test HP0-500
NO.18 Which component failure will cause a Compaq server to reset but not power up?
A. IMD
B. PPM
C. DIMM
D. CPU
Answer: B
HP practice test HP0-500 exam dumps HP0-500 exam simulations
NO.19 .After a field engineer adds a second array controller to the server, the operating system does not boot .
What is the likely cause of the problem?
A. incorrect jumper settings
B. incorrect slot order
C. array controller boot order D. interrupt conflicts
Answer: C
HP HP0-500 HP0-500 HP0-500 exam simulations
NO.20 .What can Compaq Diagnostics reliably test?
A. Compaq Insight Manager (CIM) agents
B. system ROM BIOS compatibility
C. DAT tape drive read/write function
D. non-Compaq SCSI controller
Answer: C
HP HP0-500 exam prep HP0-500 HP0-500 exam dumps HP0-500 test answers
NO.21 .On a ProLiant 450 MHz processor server, Level 2 cache is logging errors. Which item should be
replaced?
A. Cache Memory Stick
B. System I/O Board
C. CPU/Processor Module
D. Riser Card
Answer: C
HP HP0-500 HP0-500 HP0-500
NO.22 .What is the available array space after grouping six 4GB hard drives using Advanced Data Guarding?
A. 12GB
B. 16GB
C. 20GB
D. 24GB
Answer: B
HP HP0-500 certification training HP0-500 HP0-500
NO.23 .What is the first required action to safely remove an adapter from a Compaq PCI hot-pluggable slot?
A. Just remove the card.
B. Power down the slot to remove the card.
C. Power down the server to remove the card.
D. Install the new card in another slot.
Answer: B
HP HP0-500 HP0-500 HP0-500 HP0-500
NO.24 .What is the likely cause of rack instability?
A. more than one component simultaneously extended
B. UPS installed at the bottom of the rack
C. side panels not installed
D. missing blanking panels
Answer: A
HP exam dumps HP0-500 HP0-500 exam HP0-500 test questions HP0-500 practice test
NO.25 .A defective processor is replaced in a Compaq server. The 212 "System Processor Failed" POST
error will not go away. What action can be performed?
A. Erase NVRAM to clear the Health Log.
B. Run Diagnostics on memory.
C. Replace hot-pluggable power supply.
D. Replace Memory Expansion Board.
Answer: A
HP HP0-500 braindump HP0-500 braindump
NO.26 .While running Diagnostics on your ProLiant server, you receive an error code: 6092. What should you
do?
A. Replace network card.
B. Replace disk controller.
C. Connect external loopback cable.
D. Place network card in a different slot.
Answer: C
HP test HP0-500 exam HP0-500 HP0-500 HP0-500 original questions
NO.27 .When servicing a customer's system, what is the proper sequence to remove power to the server and
any external storage subsystems?
A. external storage systems first, then server
B. server first, then the external storage systems
C. UPS, then the server
D. external storage first, then the UPS
Answer: B
HP exam prep HP0-500 exam dumps HP0-500 exam
NO.28 .How is a redundant Xeon server PPM identified?
A. one processor installed
B. two processors installed
C. fully populated PPM circuit board
D. half populated PPM circuit board
Answer: C
HP HP0-500 certification HP0-500 HP0-500 braindump
NO.29 .What are the best sources for the latest versions of Rompaqs and Softpaqs? Select two.
A. Compaq ResourcePaq
B. SmartStart
C. HP/Compaq website
D. QuickFind2000
E. OS ServicePaq
Answer: B,C
HP exam simulations HP0-500 HP0-500 answers real questions
NO.30 .Where should the server Feature Board be installed in Compaq servers?
A. A designated slot
B. Any PCI 64-bit slot
C. Any extended slot
D. An EISA slot
Answer: A
HP test answers HP0-500 practice test HP0-500 HP0-500 HP0-500 braindump
ITCertMaster offer the latest 000-455 Practice Test and high-quality E20-554 PDF Exam Questions training material. Our 70-341 VCE testing engine and HP0-J60 dumps can help you pass the real exam. High-quality ICGB Exam Questions & Answers can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.itcertmaster.com/HP0-500.html
没有评论:
发表评论